Housing |
|
Installation |
Outdoor / Indoor |
UV resistance |
Yes |
Material |
Polyester, fiberglass reinforced |
Colour scheme |
RAL 7035 |
Dimensions & Weight |
|
Housing without bed-plate (width/height/depth) |
1440/1120/320mm |
Weight |
100kg |
Input parameters |
|
Permissible DC voltage (U DCmax) |
Max. <= 1100 V |
Number of DC inputs |
Max. 16 |
DC connection |
Cable lug M10 |
Fuse size |
63A-250A |
DC input current |
Max. 140A |
Output parameters |
|
Type of terminal |
Cable lug M10/M12 |
Number of DC outputs |
2 |
Output current |
Max. 2x 700A, for a short time2x1000A |
Grounding connection |
16mm²-120mm² |
Standards |
|
CE |
Conform |
Safety class & Enviromental conditions |
|
Safety class according to EN60529 |
IP 44 |
Permissible ambient temperatures |
-25 °C to +50 °C |
Rel. atmospherix humidity, non-condensing |
15% to 90% |
Altitude above sea level |
Max. 2.000 m |
Other properties |
|
Surge protection |
Typ 2 |
Optional |
|
Mounting |
Wall / SKID |
Safety class according to EN60529 |
IP 54 |
Central Box
DC Combiner
with integrated safety devices and a high safety standard
- Spatial separation of plus and minus sides
- Protection of individual DC-inputs
- Monitoring of current and voltage
- Short cabling for inverter connection
Technical Data
- Technical Data
- Download